SIS System (Version 5.6.0)

K223032

Surgical Information Sciences, Inc. · cleared 2022-11-21 · product code QIH · Radiology

Premarket evidence — what FDA accepted

Device typesamd
source quote (p.5)
The SIS System version 5.6.0 provides a patient-specific, 3D anatomical model of specific brain structures based on the patient's own clinical MR image using pre-trained deep learning neural network models.
Algorithmpre-trained deep learning neural network models
source quote (p.5)
The SIS System version 5.6.0 provides a patient-specific, 3D anatomical model of specific brain structures based on the patient's own clinical MR image using pre-trained deep learning neural network models.
Adaptive (vs locked)No
source quote (p.5)
The core algorithm that processes patient images has not changed since the prior clearance.
PCCPNo
Cybersecurity addressedFDA source did not state this

Validation studies (1)

Bench

sample size not stated

endpoints: software functions as specified; visualization accuracy of STN and GPi/GPe structures; MRI to CT registration accuracy; image processing of CT images for lead segmentation; electrode orientation; lead detection functionality

Reported performance (0 observations)

FDA source did not state a quantitative performance metric — non-reporting is itself the signal.

Each value carries its own analysis unit and task — never compare or pool across devices. Source: 510(k) summary PDF.

Predicate network

Postmarket — what happened after clearance

0
recalls in product code, 24mo
3
MAUDE reports in code, 12mo
vs code's own 3-yr baseline
2
drift signals on this device
  • re_clearance

    The FDA AI/ML device list shows a newer 510(k) K241083 (decision 2024-06-14) from Surgical Information Sciences, Inc. for a matching device line ("SIS System") — a new clearance for the same line is a change event.

    first seen 2026-07-08 · k_number:K241083

  • re_clearance

    The FDA AI/ML device list shows a newer 510(k) K230977 (decision 2023-05-02) from Surgical Information Sciences, Inc. for a matching device line ("SIS System") — a new clearance for the same line is a change event.

    first seen 2026-07-08 · k_number:K230977

Recall and MAUDE counts are product-code-level (reports aren't reliably attributable to one device); a recall is shown as device-attributed only when the recall record itself lists this clearance number. Signals are descriptive observables with sources — never a judgment that the device is unsafe or drifting. Snapshot 2026-07-08.

Reimbursement — how devices like this got paid

Not yet tracked — no payment pathway indexed for this clearance (the reimbursement corpus is a growing seed set).

Applicable FDA guidance — what the submission is measured against

FDA guidance documents and guiding principles applicable to 510(k) AI/ML devices in the Radiology panel. A curated reference index, not legal or regulatory advice — each item states its own status, and a draft is never binding.

Applicability is derived from the device's FDA advisory panel and pathway — cross-cutting guidances apply to every AI/ML device; panel-specific ones are flagged. Titles, dates, and links verified against fda.gov as of July 2026.

Constat Precedent · public FDA/CMS data · descriptive decision-support, not regulatory or reimbursement advice. Share this page: constat.dev/precedent/device/K223032